Free delivery available for selected postcodes in Victoria.

Australia's best price offered or matched!

Skip to product information
1 of 1

DINB-N180 Delkor Commercial Battery

DINB-N180 Delkor Commercial Battery

Regular price $530.00 AUD
Regular price Sale price $530.00 AUD
Sale Sold out

Technical Specifications

Specification Details
Model Delkor DINB-N180 (DIN B)
Voltage 12V
Capacity 1050 CCA | 180 Ah (20HR) | RC: 320 Min
Dimensions (LWH) 513 x 224 x 223 mm (Case Size: DIN B / N150)
Polarity / Post Type Left-Hand Positive [+ -] | Standard Tapered (SAE Standard)
Bottom Ledges None
Maintenance Maintenance-Free Accessible (Caps Included for Extreme Heat Environments)

The Delkor DINB-N180 is a premium-grade high-capacity maintenance-free starting battery designed specifically for heavy-duty commercial, agricultural, and industrial applications where extended run times and total capacity are critical requirements. Built to Delkor's unrivalled quality standards, it incorporates expanded positive and negative grids combined with high-density active materials to fight internal corrosion and power through heavy electrical cycles. This battery is the preferred choice for commercial operators seeking superior reliability in a standard DIN B footprint with a Left-Hand Positive layout.

Perfect for heavy industry operators who demand:

  • ✓ Incredible cranking capacity (1050 CCA) combined with a massive 180 Ah energy reservoir
  • ✓ Flexible engineering with accessible flush caps to allow manual topping-up if operated in extreme ambient heat conditions
  • ✓ A premium low self-discharge setup optimised to reduce maintenance overheads and machinery downtime

Key Features & Benefits

High-Durability Expanded Plates

  • • Expanded positive and negative grids form a dense, structurally sound internal grid framework
  • • Delivers exceptionally high conductivity to ensure continuous starting power (1050 CCA)
  • • Resists internal mechanical grid growth to successfully safeguard against early cell shorting

Advanced Protection & Separation

  • • High tin grid chemistry content actively repels early plate oxidation in continuous workloads
  • • Patented liquid and gas internal separator design traps rising electrolyte to prevent loss
  • • Low-resistance PE envelope separators enclose plates to shield against chemical wear

Hybrid Maintenance Layout

  • • Operates as a true maintenance-free starting cell under normal working conditions
  • • Features accessible flush caps so the unit can be topped up with distilled water if subjected to desert heat
  • • Drastically lowered self-discharge rate maximises seasonal vehicle storage capability

High-Density Active Material

  • • Custom high-density active paste maximises total chemical surface energy deployment
  • • Exceptional 320-minute reserve capacity rating sustains critical onboard auxiliary equipment
  • • Heavy-duty black polypropylene case protects components against extreme industrial impacts

Advantages & Considerations

Advantages

  • ✓ Immense 180 Ah energy output satisfies long industrial runtime requirements
  • ✓ Massive 1050 CCA provides reliable, fast ignition under extreme cold weather operations
  • ✓ Integrated accessible service ports extend total cell life in mining or harsh regional settings
  • ✓ Enhanced high-tin plates outlast entry-level conventional truck batteries

Considerations

  • • Engineered for commercial configurations; not formulated or suitable for Idle Start-Stop systems
  • • Large DIN B format weighing 41.7kg; requires appropriate machinery or dual-person physical handling
  • • Designed without bottom locking ledges; check your platform mount styles to ensure correct anchor fitment

Frequently Asked Questions

Why does a maintenance-free battery feature access caps?

While the DINB-N180 operates as a completely sealed maintenance-free battery under normal workloads, Delkor includes accessible flush caps for extreme-heat environments. In heavy-duty desert mining or agricultural applications where temperatures stay exceptionally high, the caps allow operators to top up cells with distilled water if electrolyte levels drop over years of operation.

Does this battery require continuous manual fluid level checks?

No. Under regular operating parameters, the internal patented liquid and gas separator prevents evaporation, meaning you can install it and operate completely worry-free without checking or adjusting fluid levels.

Is this battery compatible with Start-Stop vehicles?

No. The Delkor range is specifically formulated for vehicles and machinery with standard conventional electrical gear. Systems utilising smart automated idle start-stop sequences require specialised EFB or AGM platforms engineered to manage intense cyclic battery loads.

What do the DIN B and N150 casing size labels signify?

The labels specify a standardised physical dimensional footprint (513 x 224 x 223 mm) common to large European commercial platforms and global heavy machinery layouts, ensuring an easy match into heavy-duty vehicle trays.

How should I maintain this battery when my machinery is out of service?

If your vehicle or commercial machinery is stored idle for extended periods, connect a multi-stage smart commercial maintenance charger to shield the expanded plates from early sulfation and sustain optimal capacity levels.

Battery Compatibility Guide

Direct Fit & Footprint Cross-Reference

DINB-N180
DIN B / N150 Casing
12V 180Ah Left-Pos
View full details